Volume Level Control Receiver Assembly Instruction Sheet Page 4 of 4
f:\standard ioms - current release\42004 instr. manuals\42004-360b.doc
10/13
Specifications
Input voltage to VLC assembly (as applicable):
10464-001 for use in 24 V dc amplifier applications ................................... 21–28 V (25 V dc nominal)
10464-002 for use in 120 V ac amplifier applications ........................... 130–190 V (160 V dc nominal)
Input sensitivity @ 50 kHz rms +
50 Hz in ........................................ must activate by 40 mVrms maximum
Bandwidth capture range @ 300 mVrms in ........................................................... 50 kHz +
2 kHz minimum
+
5 kHz maximum